Re: Question regarding double wye usage
Posted by Terry Love on August 15, 2001 at 20:42:31:
In response to Re: Question regarding double wye usage

: I'd like to ask if a double wye can be laid flat (including an appropriate pitch) and still function appropriately receiving waste from the wye on each side. I have 2 toilets back to back that do not have room below for a straight-down waste configuration. I need to run the waste line horizontally and wanted to use a 3 inch double wye to receive each toilet and the center line in would provide the vent.

: After looking at the double wye, I am doubtful that the waste will move with the correct fluidity when laid horizontally.

Dan,
You see correctly,
The double wye works in the vertical position, but now in the horizontal.

You would be better off to aim for one of the toilets, and wye off for the second one. Keep in mind, that each toilet will still have it's own vent. Terry