Re: Temp/Pres fluxuations at shower
Posted by The Mad Plumber on March 30, 19100 at 20:08:23:
In response to Re: Temp/Pres fluxuations at shower
: JR:--If the temperature fluctuation problem is a recent development, could be that there is a dip tube problem with your water heater.
: If it is a long standing problem, or maybe one that has been accentuated by more activity in the household while your in the shower, perhaps a pressure balanced Tub/Shower valve would be the answer.
: No one likes to hear a full grown man screaming in a soprano tremolo voice each time the water goes cold..or hot. Life is much to short for these little avoidable unpleasentnesses. If it was me with the goose bump/scalding problem, I would opt for the pressure balancing Tub and shower valve. If the problem is still evident after the change, change the dip tube in the water heater and live happily ever after...Lots of luck...Bud.

Ow ow ow! Yeah, I think changing the shower valve sounds good. Hey! quite flushing that dang toilet over there while I'm taking a shower! Mad Plumber




Replies to this post
There are none.